DP Flow Meter Solutions by Process Duty

Start with the medium, operating envelope and measurement objective—then select the primary element and verification route.

APPLICATION ROUTING MATRIX

Match the process risk before choosing a meter

The same nominal pipe size can require a different differential-pressure solution when the fluid phase, pressure-loss limit, maintenance access or traceability objective changes. Use this matrix to identify the first engineering questions; final geometry and performance are confirmed from project data.

Industry, process duty, risk, suitable meter families and selection inputs
IndustryTypical dutyMain engineering risksMeter families to evaluateKey selection inputs
Oil & GasNatural gas, refinery utilities and hydrocarbon process streamsPhase condition, pressure loss, hazardous area and commercial metering basisStandard orifice, Venturi, V-ConeComposition, P/T, flow range, reporting basis, piping class
Chemical & PetrochemicalCorrosive, viscous, crystallizing or solids-bearing process mediaCompatibility, deposition, tap blockage and changing Reynolds numberWedge, balanced, standard orificeComposition, viscosity curve, solids, cleaning method, materials
Power GenerationSteam, feedwater, cooling water, combustion air and flue gasHigh P/T, thermal cycling, steam state and impulse-line managementFlow nozzle, Venturi, averaging PitotSteam state, load range, design P/T, allowable loss, pipe code
MetallurgyBlast-furnace gas, coke-oven gas, process air and large ductsDust, condensate, vibration, distorted profiles and limited accessLierba/averaging Pitot, matrix, Double-VenturiDuct geometry, velocity profile, dust, moisture, supports, access
District HeatingSteam and hot-water distribution, balancing and accountable deliverySeasonal turndown, density compensation, pressure loss and valve authoritySmartBalance ProValve, Venturi, balanced meterDemand profile, energy basis, P/T, loss budget, control philosophy

These are screening routes, not universal product claims. Standardized coefficients apply only inside the applicable standard envelope; non-standard geometries require a documented engineering or calibration basis.

DETAILED INDUSTRY GUIDANCE

Review the complete application pathway

01

Oil & Gas

Differential-pressure flow measurement for natural gas, refinery utilities, hydrocarbon liquids and process-gas duties, engineered around the governing metering objective and project specification.

Explore engineering guidance
02

Chemical & Petrochemical

Application-specific DP primary elements for corrosive, viscous, crystallizing, solids-bearing and variable process streams, with materials and maintainability considered from the start.

Explore engineering guidance
03

Power Generation

Engineered DP measurement for main and auxiliary steam, feedwater, cooling water, combustion air and flue-gas duties in power and boiler systems.

Explore engineering guidance
04

Metallurgy

Rugged flow measurement for blast-furnace and coke-oven gas, combustion air, cooling water, oxygen-service utilities and severe steelmaking processes.

Explore engineering guidance
05

District Heating

Metering and control architecture for steam and hot-water distribution, tenant sub-metering, network balancing and accountable thermal-energy delivery.

Explore engineering guidance

Ready to discuss your application?

Send your process data for an engineering review and a project-specific next step.

ISO 9001TS Licensed30+ PatentsSince 1989