DP Flow Meter Technical Articles & Engineering Guides

Selection methodology, installation best practices, standards interpretation, and calculation tutorials from our application engineering team.

AllSelection GuideTechnical FundamentalsComparisonEngineering CalculationStandards & ComplianceInstallation
Technical Fundamentals2026-09-03 · 8 min

Averaging Pitot Tube Flow Meter Guide — Principle, Installation, Limits & Selection

How multi-port pressure averaging works, why low-flow DP is difficult, what controls installation accuracy, and when to choose an averaging Pitot, orifice, wedge, or V-cone meter.

Read article
Standards & Compliance2026-07-07 · 18 min

Natural Gas Flow Measurement: AGA3, ISO 5167 and Custody Transfer

How AGA3/API MPMS 14.3 and ISO 5167-2 differ, where AGA8 real-gas properties fit, and which calculation, sampling, installation and audit controls a gas-metering specification must define.

Read article
Installation2026-07-07 · 15 min

Flow Conditioner Selection: Tubes, Vanes, Zanker Plates

Compare tube-bundle, perforated-plate and vane conditioners by validated disturbance coverage, pressure loss, fouling, installation length and uncertainty — and know when a conditioner cannot restore compliance.

Read article
Installation2026-07-07 · 17 min

Steam Flow Measurement: Best Practices and Common Pitfalls

Use IAPWS-IF97 properties, distinguish superheated from near-saturation conditions, respect the single-phase limit, and design balanced condensate legs, compensation and commissioning checks.

Read article
Standards & Compliance2026-07-07 · 16 min

DP Flow Meter Calibration and Traceability: A Complete Guide

ISO/IEC 17025 scope, flow calibration, dimensional verification, master-meter methods, uncertainty budgets, certificate review and common ways a calibration basis becomes unrepresentative.

Read article
Selection Guide2026-07-07 · 15 min

Restriction Orifice vs Metering Orifice: What's the Difference?

One measures flow under a defined metering standard; the other reduces pressure or limits flow. Learn the separate hydraulic, acoustic, mechanical and uncertainty checks for each.

Read article
Technical Fundamentals2026-07-05 · 18 min

Orifice Plate Flow Meter: Complete Technical Guide

Concentric, eccentric, and segmental orifice plates explained. The Reader-Harris/Gallagher Cd equation, β selection from 0.10–0.75, corner/flange/D-D/2 tap types, ISO 5167-2 installation tolerances, and inspection schedules — the definitive orifice plate reference.

Read article
Selection Guide2026-07-05 · 16 min

V-Cone Flow Meter: Design, Advantages & Industrial Applications

Cone-meter beta ratio, ISO 5167-5 limits, C = 0.82, the 3D or 6D bend requirements, 2D downstream length, uncertainty, and the boundary between single-phase standard use and calibrated applications.

Read article
Installation2026-07-05 · 16 min

Common DP Flow Meter Installation Errors and How to Fix Them

Six common DP installation failures — reversed plates, gasket intrusion, eccentric mounting, wrong taps, blocked impulse lines and inadequate straight run — with safe diagnostic and corrective checks.

Read article

Ready to discuss your application?

Send your process data for an engineering review and a project-specific next step.